5초록
Physiological data, such as EEG and ECG, are crucial in delivering vital information for medical diagnostics and research applications. Recently, the demand for biopotential recording using two electrodes has grown thanks to its better user experience and lower cost than counterparts with three electrodes [1,2]. However, a two-electrode recording IC suffers from a large common-mode interference (CMI) over 100VPP [3], potentially saturating an analog front-end (AFE) or resulting in large CM to differential-mode (DM) conversion. These challenges necessitate biopotential AFEs to possess a large CMI tolerance as well as a high total common-mode rejection ratio (T-CMRR) while providing excellent noise efficiency with low power consumption. Figure 15.7.1(a) depicts a simplified electrical model of CMI coupling from a power source (VPO) in a two-electrode recording system attached to a human body [4]. In a ground-isolated system, a displacement current (Id) splits into Ib and IGND, which flow through CBody and CGND, respectively. The high CM input impedance of the IA (ZIN-CM-C) converts the IGND into a large CMI voltage (VCMI-C) relative to the chip ground. The CGND represents the parasitic capacitance between floating chip ground and earth ground, which ranges from 1 to 3pF depending on the size of a recording IC and battery [4]. CMI cancellation techniques based on the CM charge pump (CMCP) in Fig. 15.7.1(b) can tolerate CMI up to 20VPP and achieve high T-CMRR [1,2,5,6]. However, these approaches introduce significant noise (> 2μVrms) and increase power consumption due to the CMCP, rendering them unsuitable for EEG measurements. An alternative method, the CM averaging unit (CMAU) reported in [7], reduces CMI by driving the chip ground to match the CMI. However, this design overlooks the CGND, making them feasible only for specific systems without the parasitic CGND. © 2025 IEEE.
- 제목
- A 4.6μW 3.3-NEF Biopotential Amplifier with 133VPPCommon-Mode Interference Tolerance and 102dB Total Common-Mode Rejection Ratio for Two-Electrode Recording System
- 저자
- Park, Yongjae; Mo, Yeong-Jin; Kim, Jeong-Hoon; Cauwenberghs, Gert; Kim, Seong-Jin
- 발행일
- 2025
- 유형
- Conference Paper
- 저널명
- Digest of Technical Papers - IEEE International Solid-State Circuits Conference
- 페이지
- 278 ~ 280