Reduction of SAR for bar type handsets with metal frame

  • Choi, Jae Hyun
  • Jang, Ju Wook
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Handsets with metal frame, which are very popular recently, cause higher SAR value due to current leakage into the metal frame. We propose a new design to reduce the SAR (Specific Absorption Rate) without degrading antenna performance which is represented by TRP (Total Radiated Power). We place the contact points between PCB GND and the metal frame at the length of lambda/2. This distributes the current over wider area and hence reduces SAR. Besides, we extend the PCB GND around the antenna feed to reduce the high current density in the area. Our experiment shows 32% reduction in SAR without degrading TRP.

키워드

SARTRPMetal FrameHandset
제목
Reduction of SAR for bar type handsets with metal frame
저자
Choi, Jae HyunJang, Ju Wook
DOI
10.1587/elex.8.103
발행일
2011-01-25
유형
Article
저널명
IEICE Electronics Express
8
2
페이지
103 ~ 108