A method to stabilize the temperature dependent performance of G-APD arrays

Citations

WEB OF SCIENCE

5
Citations

SCOPUS

10

초록

This paper presents a compensation method to stabilize the temperature dependent performance of Geiger-mode Avalanche Photodiode (G-APD) arrays for Positron Emission Tomography (PET). The compensation method is used to identify the bias voltage range that provides stable performance even at different temperatures using the G-APD's characteristics, and to control the photo-peak variation as a Function of temperature using the preamplifier gain within the identified bias voltage range. A pair of GAPD detectors and temperature sensors were located in the temperature chamber and the preamplifiers which can control the gain of the detectors using the digital potentiometer were positioned outside the chamber. The performance of the G-APD detector, especially energy resolution and coincidence timing resolution, was characterized as a function of bias voltage at different temperatures from 20 degrees C to 40 degrees C at 5 degrees C increments; the energy resolution, coincidence Liming resolution, and photo-peak position of all channels of G-APD PET defectors before and after the preamplifier gain correction were then measured and compared. The results of this study demonstrated that the optimal bias voltage range providing the good energy and coincidence Liming resolution, 12.1 +/- 1.2% and 1.30 +/- 0.09 ns, respectively, could be identified at the temperature range and the photo-peak variation and the performance at different temperatures could be stabilized by adjusting the preamplifier gain within the identified bias voltage range. We concluded the proposed method to be reliable and useful for the development of the PET system using G-APD arrays. (C) 2014 Elsevier B.V. All rights reserved,

키워드

G-APDPETTemperature effectBias voltageAmplifier gainDETECTOR
제목
A method to stabilize the temperature dependent performance of G-APD arrays
저자
Huh, YoonsukChoi, YongJung, Jin HoJung, Jiwoong
DOI
10.1016/j.nima.2014.11.006
발행일
2015-02-01
유형
Article
저널명
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
772
페이지
83 ~ 88