Gas-liquid mass transfer coefficient of methane in bubble column reactor

Citations

WEB OF SCIENCE

31
Citations

SCOPUS

31

초록

Biological conversion of methane gas has been attracting considerable recent interest. However, methanotropic bioreactor is limited by low solubility of methane gas in aqueous solution. Although a large mass transfer coefficient of methane in water could possibly overcome this limitation, no dissolved methane probe in aqueous environment is commercially available. We have developed a reactor enabling the measurement of aqueous phase methane concentration and mass transfer coefficient (k(L)a). The feasibility of the new reactor was demonstrated by measuring k(L)a values as a function of spinning rate of impeller and flow rate of methane gas. Especially, at spinning rate of 300 rpm and flow rate of 3.0 L/min, a large k(L)a value of 102.9 h (1) was obtained.

키워드

Methane; Mass Transfer Coefficient; Bubble Column Reactor; Shale Gas; SOLUBILITY; SOIL
제목
Gas-liquid mass transfer coefficient of methane in bubble column reactor
저자
Lee, Jaewon; Yasin, Muhammad; Park, Shinyoung; Chang, In Seop; Ha, Kyoung-Su; Lee, Eun Yeol; Lee, Jinwon; Kim, Choongik
DOI
10.1007/s11814-014-0341-7
발행일
2015-06
유형
Article
저널명
Korean Journal of Chemical Engineering
권
32
호
6
페이지
1060 ~ 1063