Cell-based chip for the detection of anticancer effect on HeLa cells using cyclic voltammetry

  • El-Said, Waleed Ahmed
  • Yea, Cheol-Heon
  • Kim, Hyunhee
  • Oh, Byung-Keun
  • Choi, Jeong-Woo
Citations

WEB OF SCIENCE

65
Citations

SCOPUS

70

초록

HeLa cells directly immobilized on gold-patterned silicon substrate were used to assess the biological toxicity of anticancer drugs (hydroxyurea and cyclophosphamide). Immobilization of HeLa cells was confirmed by optical microscopy, and cell growth, viability and drug-related toxicity were examined by cyclic voltammetry and potentiometric stripping analysis. The voltammetric behaviors of HeLa cells displayed a quasi-reversible pattern with the peak current exhibiting a linear relationship with cell number. The attached living cells were exposed to different concentrations of hydroxyurea and cyclophosphamide as anticancer drugs, which induced the change of cyclic voltammetry current peak. As the exposed concentration of anticancer drugs was increased, the change of current peak was increased, which indicates the decrease of cell viability. Trypan Blue dyeing was performed to confirm the results of the effect of anticancer drugs on the cell viability which was obtained from cyclic voltammetry assay. The proposed direct cell immobilization method technique can be applied to the fabrication of cell chip for diagnosis, drug detection, and on-site monitoring. (C) 2008 Elsevier B.V. All rights reserved.

키워드

Cell-based chipCyclic voltammetryPotentiometric stripping analysisHeLa cellNanobiochipAnticancer drug sensitivitySINGLE-CELLDIFFERENTIATIONIMMOBILIZATIONFABRICATIONBEHAVIORSENSORSMODELASSAY
제목
Cell-based chip for the detection of anticancer effect on HeLa cells using cyclic voltammetry
저자
El-Said, Waleed AhmedYea, Cheol-HeonKim, HyunheeOh, Byung-KeunChoi, Jeong-Woo
DOI
10.1016/j.bios.2008.07.037
발행일
2009-01-01
유형
Article; Proceedings Paper
저널명
Biosensors and Bioelectronics
24
5
페이지