상세 보기
Triple-pulse Method for Monitoring Formate in CO2 Conversion Process
- Jeong, Soojin;
- Shin, Woonsup
Citations
WEB OF SCIENCE
2Citations
SCOPUS
2초록
In CO2-to-formic-acid process, real-time monitoring of formate is pivotal for the efficient control of the process. A stable sensing method that is suitable for measuring the high concentrations of formate produced during this process is required. Here, we developed a triple-potential-step method to monitor the formate in the range of 0.1 to 2.0 M and showed that a long-term, continuous monitoring is possible. Among the Pd-, Pt-, and Au-electrode materials tested, Au was the best option due to its low sensitivity and its stability in formate oxidation.
키워드
Electrochemical sensor; Formate monitoring; CO2 conversion; CO2 to formate; FORMIC-ACID; CARBON-DIOXIDE; ELECTROCHEMICAL REDUCTION; FUEL-CELLS; OXIDATION
- 제목
- Triple-pulse Method for Monitoring Formate in CO2 Conversion Process
- 저자
- Jeong, Soojin; Shin, Woonsup
- 발행일
- 2016-07
- 유형
- Article
- 저널명
- Electroanalysis
- 권
- 28
- 호
- 7
- 페이지
- 1437 ~ 1440