The fabrication of functional biosurface composed of iron storage protein, ferritin

  • Choi, Jeong-Woo
  • Kim, Young Jun
  • Kim, Sang-Uk
  • Min, Junhong
  • Oh, Byung-Keun
Citations

WEB OF SCIENCE

15
Citations

SCOPUS

17

초록

A functional biosurface applicable to a biomemory device was fabricated using ferritin, which is one of the globular protein complexes consisting of 24 protein subunits, which can be classified as metalloproteins. For the fibrication of uniform ferritin layer, 11-MUA(11-mercaptoundecanoic acid) was used as a linker material. The formation of the ferritin layer was confirmed by surface plasmon resonance (SPR) spectroscopy, and the morphology of the immobilized ferritin was analyzed by scanning tunneling microscopy (STM). The electrochemical redox property investigation was accomplished by the cyclic voltammetry (CV) technique. These results of adsorbed ferritin on the modified electrode can be used for the fabrication of bioelectronics. (c) 2008 Elsevier B.V. All rights reserved.

키워드

ferritinbiomemorysurface plasmon resonance (SPR)scanning tunneling microscopy (STM)cyclic voltammetry (CV)SURFACE-PLASMON RESONANCEPSEUDOMONAS-AERUGINOSA AZURIN
제목
The fabrication of functional biosurface composed of iron storage protein, ferritin
저자
Choi, Jeong-WooKim, Young JunKim, Sang-UkMin, JunhongOh, Byung-Keun
DOI
10.1016/j.ultramic.2008.04.046
발행일
2008-09
유형
Article; Proceedings Paper
저널명
Ultramicroscopy
108
10
페이지
1356 ~ 1359