Establishment of a fabrication method for a long-term actuated hybrid cell robot

  • Kim, Jinseok
  • Park, Jungyul
  • Yang, Sungwook
  • Baek, Jeongeun
  • Kim, Byungkyu
  • 외 4명
Citations

WEB OF SCIENCE

118
Citations

SCOPUS

138

초록

We developed a novel method to fabricate a crab- like microrobot that can actuate for a long period in a physiological condition. The microrobot backbone was built with a biocompatible and elastic material - polydimethylsiloxane ( PDMS) - by using a specially designed 3D molding aligner, and consisted of three strips of PDMS "legs'' connected across a "body.'' Cardiomyocytes were then plated on the grooved top surface of the backbone, resulting in a high concentration of pulsating cells. These key techniques enabled the microrobot to walk continuously for over ten days. The performance of our crab- like microrobot was measured at an average velocity of 100 mm s(-1), and the estimated total distance it travelled was 50 m over a one-week period. Thus, we have demonstrated for the first time a walking robot that exhibited reliable and long-term actuation performances.

키워드

PDMSPOLYDIMETHYLSILOXANECARDIOMYOCYTESF-1-ATPASETOPOGRAPHYSYSTEMSDEVICESMOTOR
제목
Establishment of a fabrication method for a long-term actuated hybrid cell robot
저자
Kim, JinseokPark, JungyulYang, SungwookBaek, JeongeunKim, ByungkyuLee, Sang HoYoon, Eui-SungChun, KukjinPark, Sukho
DOI
10.1039/b705367c
발행일
2007
유형
Article
저널명
Lab on a Chip - Miniaturisation for Chemistry and Biology
7
11
페이지
1504 ~ 1508