Anodic stripping voltammetry (ASV) is successfully applied in mM level detection of mercury ion in an electroplating bath which is currently used in preparing a cathodic electrolyzer. Glassy carbon electrode is used for the detection and the optimum condition obtained is 10 s deposition at - 1.4 V vs. Ag/AgCl and stripping by scanning from - 1.4 to + 0.4 V vs Ag/AgCl at 50 mV/s. By applying the method, the mercury ion concentration in the electroplating bath could be successfully monitored during the plating.