EXPERIMENTAL STUDY ON BASIC PERFORMANCE OF ELECTROOSMOTIC PUMP WITH ION EXCHANGING POROUS GLASS SLIT

  • Lee, Ho; 
  • Kim, Gyu Man; 
  • Lee, Choon Young; 
  • Park, Cheol Woo; 
  • Kim, Dae Joong
Citations

WEB OF SCIENCE

4
Citations

SCOPUS

4

초록

The basic concept and preliminary performance results of a miniaturized electroosmotic pump with diaphragms were included in the present study. The separation of an electroosmotic pumping liquid from a drug using diaphragms is mainly to have a freedom in choosing an electroosmotic pumping liquid and to achieve the optimal drug delivery with its preferable precise control. As a result, the maximum flow rate and current increased linearly according to the increment of applied voltage that is electric potential.

키워드

Electroosmotic Pump; Performance; Diaphragm; Electric Potential
제목
EXPERIMENTAL STUDY ON BASIC PERFORMANCE OF ELECTROOSMOTIC PUMP WITH ION EXCHANGING POROUS GLASS SLIT
저자
Lee, Ho; Kim, Gyu Man; Lee, Choon Young; Park, Cheol Woo; Kim, Dae Joong
DOI
10.1142/S0217979210065374
발행일
2010-06-30
유형
Article; Proceedings Paper
저널명
International Journal of Modern Physics B
권
24
호
15-16
페이지
2627 ~ 2632