Polyaniline Based Catalase Biosensor for the Detection of Hydrogen Peroxide and Azide

Citations

WEB OF SCIENCE

24
Citations

SCOPUS

26

초록

The CAT/PANi/ITO bioelectrode has been prepared as a catalase biosensor and shows response for monitoring not only of H2O2 but also azide. The sensor exhibited an excellent response to the H2O2 and azide. The linear range of H2O2 was 0.064 similar to 1 mM and for azide 0.125 similar to 4 mM, respectively. Catalase biosensor was based on the principle of the measurements as the decrease in the differentiation of oxygen level, which has been caused by the inhibition of catalase in the bioactive layer of the biosensor by azide. The repeatability experiments were done in triplicate. The logarithm response of the biosensor to H2O2 (r(2) = 0.99), as well as, for azide (r(2) = 0.90) were reported, respectively. The bioelectrode was characterized by CV and AFM. The proposed biosensor would be applied for the determination of H2O2 and azide in various biological samples. (C) KSBB

키워드

Polyaniline (PANi)catalase (CAT)hydrogen peroxide (H2O2)azidebiosensorbioelectrodeSODIUM-AZIDEIMMOBILIZATIONELECTRODEFABRICATIONINHIBITIONPROTEIN
제목
Polyaniline Based Catalase Biosensor for the Detection of Hydrogen Peroxide and Azide
저자
Singh, Ravindra P.Kang, Da-YeonOh, Byung-KeunChoi, Jeong-Woo
DOI
10.1007/s12257-008-0267-1
발행일
2009-07
유형
Article
저널명
Biotechnology and Bioprocess Engineering
14
4
페이지
443 ~ 449