Electrochemical sensor based on direct electron transfer of HIV-1 Virus at Au nanoparticle modified ITO electrode

Citations

WEB OF SCIENCE

45
Citations

SCOPUS

51

초록

In this study, for the first time, an electrochemical detection method was proposed to detect direct electron transfer signal from HIV-1 Virus. Au nanoparticles were fabricated on the Indium Tin Oxide coated glass (ITO) electrode by electrochemical deposition to improve the surface area to provide better electron-transfer kinetics, and higher background charging current. On the Au nanoparticle modified ITO electrode, antibody fragment was immobilized by self-assembly method with gold-thiol interaction and different concentrations of HIV-1 Virus like particles (VLPs) were applied for the direct determination. Due to the advantage of fabricated Au nanoparticle's excellent electrical and mechanical properties, HIV-1 VLPs were successfully detected from 600 fg/mL to 375 pg/mL. Furthermore, since the proposed electrochemical virus sensor is designed for direct determination without any labeling structure, the electrochemical communication between redox target and electrode surface will reduce interference reactions and simplifies the detection system with small amount of reagent and better stability. Therefore, highly sensitive virus sensor was developed to detect HIV-1 Virus in a label free system. (c) 2013 Elsevier B.V. All rights reserved.

키워드

Electrochemical sensorVirusNanoparticleHIV-1Direct electron transferP24 ANTIGENGLUCOSEENZYMEDNAIMMUNOSENSORBIOSENSORSINFECTIONPROBES
제목
Electrochemical sensor based on direct electron transfer of HIV-1 Virus at Au nanoparticle modified ITO electrode
저자
Lee, Jin-HoOh, Byeung-KeunChoi, Jeong-Woo
DOI
10.1016/j.bios.2013.06.010
발행일
2013-11-15
유형
Article
저널명
Biosensors and Bioelectronics
49
페이지
531 ~ 535