Characterization of neuron signaling using microelectrode array combined with fast and precise cooling device for cryoanesthesia

  • Kim, Jaehyun; 
  • Lee, Jong Seung; 
  • Noh, So yeon; 
  • Lee, Nuree; 
  • Lee, Jung Chul; 
  • ... Park, Jung yul; 
  • 외 3명
Citations

SCOPUS

0

초록

Cryoanesthesia technology is effective on treatment of a skin surface as a purely physical technique without side effects, and study of cryoanesthesia in cellular level are need to improve its technology but there has been a lack of its study so far. Here, we introduce a novel platform for cryo-neuromodulation, which is composed of a microelectrode array (MEA) system and a high-speed and precise probe type cooling device that provides localized cooling temperature. We investigate the potential of cryo-neuromodulation by exploring temperature conditions (temperature and duration time) that cause block and recovery of neuron signal without cell damages. © 2019 CBMS-0001.

키워드

Cooling device; Cooling experiment; Cryo-neuromodulation; Cryoanesthesia; Neuron cooling
제목
Characterization of neuron signaling using microelectrode array combined with fast and precise cooling device for cryoanesthesia
저자
Kim, Jaehyun; Lee, Jong Seung; Noh, So yeon; Lee, Nuree; Lee, Jung Chul;  Kim, Tae sung;  Kim, Gun ho; Cho, Seung Woo; Park, Jung yul
발행일
2019
유형
Conference Paper
저널명
23rd International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2019
페이지
787 ~ 788