Aeration Control of Thermophilic Aerobic Digestion Using Fluorescence Monitoring

Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy, costs clue to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already, reduced the heating cost. However, only, a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3%, reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate.

키워드

Waste activated sludgethermophilic aerobic digestionfluorescenceaeration controlstabilizationSTRENGTH AGRICULTURAL WASTEVOLATILE FATTY-ACIDSSLUDGE-DIGESTIONDUAL DIGESTIONSEWAGE-SLUDGEOXYGENCELLSPHBIODEGRADATIONBIOPROCESSES
제목
Aeration Control of Thermophilic Aerobic Digestion Using Fluorescence Monitoring
저자
Kim, Young-KeeOh, Byung-Keun
DOI
10.4014/jmb.0803.206
발행일
2009-01
유형
Article
저널명
Journal of Microbiology and Biotechnology
19
1
페이지
93 ~ 98