Development of a multiplexed readout with high position resolution for positron emission tomography

Citations

WEB OF SCIENCE

17
Citations

SCOPUS

19

초록

Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high resolution PET detector block composed of 2x3 detector modules, each consisting of an 8x8 array of 1.52x1.52x6 mm(3) LYSO, a 4x4 array of 3x3 mm(2) silicon photomultiplier (SiPM) and 13.4x13.4 mm(2) light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7 1.6% full-width-at-half-maximum (FWHM) and the peak-to valley ratios of the flood histogram on the horizontal and vertical lines were 18.8 +/- 0.8 and 22.8 +/- 1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 ram could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

키워드

Positron emission tomographySilicon photomultiplier (SiPM)Multiplexing circuitHigh resolutionSENSITIVE PHOTOMULTIPLIER TUBESSMALL-ANIMAL PETSILICON PHOTOMULTIPLIERDETECTORSARRAYSCRYSTALSSCANNER
제목
Development of a multiplexed readout with high position resolution for positron emission tomography
저자
Lee, SangwonChoi, YongKang, JihoonJung, Jin Ho
DOI
10.1016/j.nima.2017.01.026
발행일
2017-04-01
유형
Article
저널명
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
850
페이지
42 ~ 47