New Adaptive Clutter Rejection Based on Spectral Analysis for Ultrasound Color Doppler Imaging: Phantom and In Vivo Abdominal Study

  • Park, Geunyong
  • Yeo, Sunmi
  • Lee, Jae Jin
  • Yoon, Changhan
  • Koh, Hyun-woo
  • ... Yoo, Yangmo
  • 외 3명
Citations

WEB OF SCIENCE

7
Citations

SCOPUS

8

초록

Effective rejection of time-varying clutter originating from slowly moving vessels and surrounding tissues is important for depicting hemodynamics in ultrasound color Doppler imaging (CDI). In this paper, a new adaptive clutter rejection method based on spectral analysis (ACR-SA) is presented for suppressing nonstationary clutter. In ACR-SA, tissue and flow characteristics are analyzed by singular value decomposition and tissue acceleration of backscattered Doppler signals to determine an appropriate clutter filter from a set of clutter filters. To evaluate the ACR-SA method, 20 frames of complex baseband data were acquired by a commercial ultrasound system equipped with a research package (Accuvix V10, Samsung Medison, Seoul, Korea) using a 3.5-MHz convex array probe by introducing tissue movements to the flow phantom (Gammex 1425 A LE, Gammex, Middleton, WI, USA). In addition, 20 frames of in vivo abdominal data from five volunteers were captured. From the phantom experiment, the ACR-SA method provided 2.43 dB (p<0.001) and 1.09 dB (p<0.001) improvements in flow signal-to-clutter ratio (SCR) compared to static (STA) and down-mixing (ACR-DM) methods. Similarly, it showed smaller values in fractional residual clutter area (FRCA) compared to the STA and ACR-DM methods (i.e., 2.3% versus 5.4% and 3.7%, respectively, p<0.001). The consistent improvements in SCR from the proposed ACR-SA method were obtained with the in vivo abdominal data (i.e., 4.97 dB and 3.39 dB over STA and ACR-DM, respectively). The ACR-SA method showed less than 1% FRCA values for all in vivo abdominal data. These results indicate that the proposed ACR-SA method can improve image quality in CDI by providing enhanced rejection of nonstationary clutter.

키워드

Adaptive clutter rejectionnonstationary clutterspectral analysisultrasound color Doppler imaging (CDI)SINGULAR-VALUE DECOMPOSITIONFILTER DESIGNFLOWPERFORMANCEESTIMATOR
제목
New Adaptive Clutter Rejection Based on Spectral Analysis for Ultrasound Color Doppler Imaging: Phantom and In Vivo Abdominal Study
저자
Park, GeunyongYeo, SunmiLee, Jae JinYoon, ChanghanKoh, Hyun-wooLim, HyungjoonKim, YoungtaeShim, HwanYoo, Yangmo
DOI
10.1109/TBME.2013.2276088
발행일
2014-01
유형
Article
저널명
IEEE Transactions on Biomedical Engineering
61
1
페이지
55 ~ 63